Silicon-photonics optoacoustic sensor for fully wearable blood pressure monitoring.

An illustration of the test subject during the measurement.

Nature Communications volume 17, Article number: 10931 (2026)

Gil Gelbert, Ron Moisseev, Yoav Hazan, Tamar Harary, Daniel H. Lange & Amir Rosenthal

Abstract:

Cuffless blood pressure monitoring is essential for continuous cardiovascular assessment. Current wearable approaches rely on pulse-echo ultrasound patches that track pulsating arterial diameters. However, multi-element designs and precise alignment complicate their applicability as a fully wearable solution. We overcome these challenges by using a highly miniaturized silicon-photonics acoustic detector and optoacoustic excitation to generate ultrasound waves inside the artery. The superior contrast in these optoacoustic signals and the detector’s semi-isotropic sensitivity enable robust artery diameter monitoring with a single detection element, achieving high tolerance to translation and rotation. The detector’s high sensitivity, achieved despite its small size, enables measuring optoacoustic signals from the radial artery with a high contrast at 100 Hz, capturing the features of the blood pressure waveform. Here, we show that the device’s agreement with a reference cuff-based blood pressure monitor highlights the potential of silicon-photonics optoacoustic sensing as a practical solution for continuous, cuffless monitoring in daily life.

A wearable optoacoustic sensor targeting the radial artery close to the wrist.
A wearable optoacoustic sensor targeting the radial artery close to the wrist.

a. A wearable optoacoustic sensor targeting the radial artery close to the wrist. The sensor is connected to a console that reads out the optoacoustic signals and converts them into the BP (blood pressure) waveforms. The results are compared to a reference system on the finger. b, c The sensor is positioned on the skin above the radial artery with an unknown yaw angle, which depends mainly on the placement, and an unknown pitch, which depends mostly on the vertical orientation of the artery itself. d The operational end of the sensor, showing the illumination pattern and the SPADE (silicon photonics acoustic detector), which is coupled with two PM (polarization-maintaining) optical fibers. e The optoacoustic sensing procedure involves an excitation light from the sensor that diffuses in the tissue and induces outward-propagating US (ultrasound) waves inside the artery that reach the SPADE. f During each cardiac cycle, a pressure pulse travels down the arterial tree, altering the arterial diameter. The optoacoustic signal is used to directly measure the arterial diameter, and a physiological algorithm is used to convert it to a BP value. g The structure of the SPADE is shown, where the pressure-sensitive volume is the section of the WG (waveguide) marked in red.

Nature Communications volume 17, Article number: 10931 (2026)

Gil Gelbert, Ron Moisseev, Yoav Hazan, Tamar Harary, Daniel H. Lange & Amir Rosenthal

In vivo optical-resolution optoacoustic flow cytometry in the oral mucosa using a transparent silicon-photonics acoustic detector (SPADE).

Integrated in vivo measurement setup

Photoacoustics Article: 100866 Volume: Volume 51

Tamar Harary, Gil Gelbert, Ron Moisseev, Amir Rosenthal

Abstract:

Complete blood counts are central to clinical practice but require invasive sampling and centralized laboratory analysis. Optical-resolution photoacoustic microscopy provides intrinsic specificity to red blood cells (RBCs) through hemoglobin absorption. However, conventional implementations typically depend on bulky acoustic coupling schemes that hinder clinical translation. Here, we present a compact and integrable, label-free optoacoustic platform that combines optical-resolution excitation in an epi-illumination geometry with a transparent silicon-photonics acoustic detector (SPADE) featuring a wide acoustic acceptance angle that enables detection without strict optical–acoustic co-alignment. System performance was first characterized using optoacoustic point sources and subsequently evaluated in controlled RBC flow experiments within a tapered glass-capillary microfluidic phantom, as well as in vivo measurements of superficial inner-lip capillaries in human volunteers. The transparent SPADE preserved tight optical focusing (≤ 4 µm) and provided an acoustic bandwidth exceeding 100 MHz with a noise-equivalent pressure of approximately 2.3 mPa/Hz¹ ᐟ². Single-RBC transients were robustly detected in the phantom across varying flow conditions, while in vivo measurements at multiple capillary sites yielded reproducible transient signals consistent with individual RBC passages. These results establish a practical framework for stable, fixed-position optoacoustic detection of individual RBCs in superficial human capillaries, demonstrating the potential of transparent SPADE-based systems for non-invasive blood analysis.

Integrated in vivo measurement setup.

(a) CAD rendering of the compact and portable device showing the optoacoustic excitation channel, optical microscope imaging channel, and illumination path, with the transparent SPADE sensor positioned at the front of the system. (b) Semi-transparent view illustrating the beam steering mechanism (pan and tilt adjustment), together with the mechanical linear stage and objective configuration used for precise positioning of the optical focus. (c) Complete experimental setup mounted on a three-axis translation stage, enabling accurate positioning of the device during measurements. (d) Mechanical design of the lip holder used to stabilize the subject during measurements. (e) Photograph of the system during alignment and calibration, demonstrating the compact and integrated configuration prior to measurements. (f) Representative in vivo measurement configuration showing the device positioned in front of a volunteer’s lip for capillary imaging.
.

Photoacoustics Article: 100866 Volume: Volume 51

Tamar Harary, Gil Gelbert, Ron Moisseev, Amir Rosenthal