In vivo optical-resolution optoacoustic flow cytometry in the oral mucosa using a transparent silicon-photonics acoustic detector (SPADE).

Photoacoustics Article: 100866 Volume: Volume 51

Tamar Harary, Gil Gelbert, Ron Moisseev, Amir Rosenthal

Abstract:

Complete blood counts are central to clinical practice but require invasive sampling and centralized laboratory analysis. Optical-resolution photoacoustic microscopy provides intrinsic specificity to red blood cells (RBCs) through hemoglobin absorption. However, conventional implementations typically depend on bulky acoustic coupling schemes that hinder clinical translation. Here, we present a compact and integrable, label-free optoacoustic platform that combines optical-resolution excitation in an epi-illumination geometry with a transparent silicon-photonics acoustic detector (SPADE) featuring a wide acoustic acceptance angle that enables detection without strict optical–acoustic co-alignment. System performance was first characterized using optoacoustic point sources and subsequently evaluated in controlled RBC flow experiments within a tapered glass-capillary microfluidic phantom, as well as in vivo measurements of superficial inner-lip capillaries in human volunteers. The transparent SPADE preserved tight optical focusing (≤ 4 µm) and provided an acoustic bandwidth exceeding 100 MHz with a noise-equivalent pressure of approximately 2.3 mPa/Hz¹ ᐟ². Single-RBC transients were robustly detected in the phantom across varying flow conditions, while in vivo measurements at multiple capillary sites yielded reproducible transient signals consistent with individual RBC passages. These results establish a practical framework for stable, fixed-position optoacoustic detection of individual RBCs in superficial human capillaries, demonstrating the potential of transparent SPADE-based systems for non-invasive blood analysis.

Integrated in vivo measurement setup.

(a) CAD rendering of the compact and portable device showing the optoacoustic excitation channel, optical microscope imaging channel, and illumination path, with the transparent SPADE sensor positioned at the front of the system. (b) Semi-transparent view illustrating the beam steering mechanism (pan and tilt adjustment), together with the mechanical linear stage and objective configuration used for precise positioning of the optical focus. (c) Complete experimental setup mounted on a three-axis translation stage, enabling accurate positioning of the device during measurements. (d) Mechanical design of the lip holder used to stabilize the subject during measurements. (e) Photograph of the system during alignment and calibration, demonstrating the compact and integrated configuration prior to measurements. (f) Representative in vivo measurement configuration showing the device positioned in front of a volunteer’s lip for capillary imaging.
.

Photoacoustics Article: 100866 Volume: Volume 51

Tamar Harary, Gil Gelbert, Ron Moisseev, Amir Rosenthal